DRL-48V240W1EN

Rp 980.670

Description

Output Voltage48 V
Output Voltage Range43.2-52.8 V
Output Current5:00 AM
Output Power240 W
PARD (20 MHz)< 200 mVpp @ 0°C to +70°C
< 600 mVpp @ -30°C to 0°C
Hold-up Time20 ms typ @ 115 VAC
20 ms typ @ 230 VAC
Phase InputSingle Phase
Input Voltage Range90-264 VAC
Input Frequency47-63 Hz
Input Current 2.5 A typ @ 115 VAC
 1.3 A typ @ 230 VAC
Efficiency at 100% Load (At 25°C ambient temperature by vertical mounting orientation.)90.5 % typ At 230 VAC
Max Inrush Current (Cold Start)40 A typ @ 230 VAC
Power Factor0.95
Leakage Current< 0.75 mA @ 240 VAC
Case Cover / ChassisSGCC / Aluminium
Dimensions (H × W × D) mm123.6 × 40 × 116.8
Unit Weight0.62 kg
Cooling SystemConvection
MTBF (as per Telcordia SR-332 (I/P: 115 VAC & 230 VAC, O/P: 100% load) for vertical mounting orientation.)> 700,000 hrs
Operating Temperature-30°C to +70°C
Storage Temperature-40°C to +85°C
Operating Humidity20 to 90% RH (Non-Condensing)
Operating Altitude0 to 5,000 m (0 to 16,400 ft)